    ISO 15189 Lab Software: What Your LIS Must Support

    What ISO 15189 asks of a laboratory information system: test catalogue, sample traceability, authorisation, amended reports, audit trail and quality control.

    22 November 20265 min read

    ISO 15189 accredits the laboratory, not the software, but the standard expects the laboratory information system to keep the evidence an assessor will ask for. In practice that means a controlled test catalogue with reference intervals, full sample traceability from collection to report, authorisation by competent staff, a proper process for amended reports, an audit trail of every change, and internal quality control that can stop a result being released. This guide explains each requirement in plain terms and what to look for in a system.

    What does ISO 15189 expect from laboratory software?

    ISO 15189 sets requirements for quality and competence in medical laboratories. It covers the whole process, from the request and the sample through examination to the report, and it asks the laboratory to control the information systems it relies on, including who can access them and how data is protected.

    No software makes a laboratory compliant on its own. Accreditation depends on people, procedures, equipment and evidence. What a good system does is make the right way of working the easy way, and keep a record that shows an assessor what actually happened.

    HealthOS 24 laboratory screen showing result entry with reference ranges and flags
    Results carry their units, reference interval and flag from the moment they are entered.

    Which LIS functions map to the standard?

    The table links the main areas of the standard to the system functions that support them. Use it as a checklist when reviewing your current system or a new one.

    ISO 15189 areas and the LIS functions that support them
    AreaWhat the LIS should doEvidence it keeps
    Test catalogueHold methods, units and reference intervalsVersion of the interval used
    Pre examinationTrack collection, receipt and rejectionTimes, condition and reasons
    IdentificationUnique accession and labelsSample linked to patient and order
    AuthorisationRelease only by permitted staffWho entered and who authorised
    Amended reportsRequire a reason and keep the originalVersion history of each result
    Quality controlEvaluate control runs and act on failureRuns, rules broken, corrective action
    Critical resultsPrompt and record the callWho was told and when

    Why does the test catalogue matter so much?

    The catalogue is where many reporting errors begin. A single normal range per analyte cannot report haemoglobin, creatinine or ferritin correctly for men, women and children, and qualitative tests or cultures do not fit a numeric grid at all.

    Just as important, the interval printed on a report must be the one that applied when the result was issued. If editing a reference range quietly changes every historical report, a reprint can show different flags from the original. The system should store the interval with each result.

    How should sample traceability work?

    The pre examination phase is where a large share of laboratory error happens, so the record has to show what was collected, when, by whom, in which container, and in what condition it arrived. A report should state the collection time, not the time the request was typed.

    • A unique accession number and barcode label for each specimen
    • Collection and receipt times recorded separately
    • Rejection with a reason from a controlled list, such as haemolysed or clotted
    • Send out tests tracked to the referral laboratory and back

    How should verification and amended reports be controlled?

    The standard expects results to be reviewed and released by authorised, competent staff. The system should restrict release to the people the laboratory has authorised and record who entered and who released every result, so that any self release is visible.

    Once a report is issued, changing it is a different act. An amendment should need its own permission and a written reason, keep the original value, and print clearly as amended. Critical results should not be released until the call to the clinician has been logged.

    How does HealthOS 24 support ISO 15189 work?

    HealthOS 24 is not certified to ISO 15189, and no software can be, but its laboratory module is built around the evidence the standard asks for. The test catalogue holds analytes with units, LOINC codes and reference intervals by sex and age, and each result stores the interval that was applied. Specimens get accession numbers and barcode labels, with collection and receipt times and rejection reasons.

    Authorisation is a permission the laboratory grants to named roles, and the record shows who entered and who authorised each report. Amending an issued result needs a separate permission and a reason, keeps a version history and prints an amended banner. Internal quality control uses Westgard rules and Levey Jennings charts, and a failed run stops results for that analyte being authorised until it is resolved or overridden with a reason. Critical values need a logged call before release.

    Conclusion

    ISO 15189 is achieved by the laboratory, but the laboratory information system decides how much of the evidence is captured automatically and how much is chased on paper. Look for a catalogue that freezes the interval with the result, full sample traceability, controlled authorisation and amendment, and quality control that can stop a release. With those in place, assessments become a matter of showing the record rather than reconstructing it.

    Frequently asked questions

    Can laboratory software be ISO 15189 certified?

    No. ISO 15189 accreditation applies to the medical laboratory. Software supports the laboratory's quality system and must be validated by the laboratory for its own use.

    Does ISO 15189 require a pathologist to authorise every result?

    The standard asks for review and release by authorised, competent staff. Who that is depends on the laboratory's own procedures and local regulation, so define it in your quality manual.

    What is the difference between a corrected and an amended report?

    Laboratories use the terms differently, but both mean a report changed after issue. Whatever you call it, keep the original, record the reason and make the change visible to the reader.

    What are Westgard rules?

    They are a set of statistical rules for judging internal quality control results against the expected mean and standard deviation, used to decide whether an analytical run can be accepted.